222 A-Modell - 11/12 - Ausgabe 09/11 - 2096161 - BUE-0036-10EN
Troubleshooting
14
14.3 Fuel cell
14.4 Gas system
Z Do not open the fuel cell. The fuel cell contains no parts that could be
repaired by itself.
Z All faults are not displayed. If the faults cannot be rectified using the fol-
lowing table or the instruction manual for the fuel cell, please contact the
customer service.
Fault (display) Cause Remedy
Fuel cell cannot be
switched on
No battery connected,
battery connected incor-
rectly or totally dis-
charged
Inspect the connection
Fuse is defective Replace fuse; if it hap-
pens again, contact the
customer service
Failure: Environment too
warm
Ambient temperature too
high (40 °C)
Fuel cell restarts when
the ambient temperature
is between 0 °C and
40 °C
X In case of a defect of the gas system (gas odour, high gas consumption)
there is danger of explosion! Close regulator tap on the gas bottle imme-
diately. Open doors and windows and ventilate well.
X If the gas system is defective: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.).
X Have the defective gas system repaired by an authorised specialist
workshop.
Fault Cause Remedy
No gas Gas bottle is empty Change gas bottle
Gas isolator tap closed Open the gas isolator tap
Regulator tap on the gas
bottle is closed
Open regulator tap on
the gas bottle
External temperature is
too low (-42 °C for pro-
pane gas, 0 °C for bu-
tane gas)
Wait for higher external
temperatures
Built-in appliance is de-
fective
Contact customer service