TECHNICAL & SERVICE MANUAL
OUTDOORUNIT: AE4MI91AH
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
AE4MI91AH
Destination: General area (50Hz)
Europe (50Hz)
Australia (50Hz)
General area (60Hz)
Indoor Model No. Product Code No.
AE4MI91AH
IMPORTANT
These air conditioners employ new
refrigerant R410A.
Pay special attention when
servicing the unit.
4-room multi Outdoor unit
< Combined Indoor Units >
1. How these units may be combined is given in
the Unit Combination Tables in the Appendix.
2. Be sure to operate the air conditioning
system only when 2 or more indoor units
have been installed. If operated with only a
single unit installed, the returning fluid to the
compressor may cause a malfunction.
NOTE
Wall mounted type
AWMI28AHL
AWMI38AHL
AWMI50AHL
AWMI70AHL
Capacity
9.0 kW
W
NOV.2003
Vista de pagina 0
1 2 3 4 5 6 ... 44 45

Indice de contenidos

Pagina 1 - OUTDOORUNIT: AE4MI91AH

TECHNICAL & SERVICE MANUALOUTDOORUNIT: AE4MI91AHDC INVERTER MULTI-SYSTEM AIR CONDITIONERAE4MI91AHDestination: General area (50Hz)Europe (50Hz)Aus

Pagina 2 - Please Read Before Starting

5. PERFORMANCE DATA5-1. Performance Charts (4-room multi)725876530 35 402520181614121030 35 40–50 5987610 15 20 25–50 5106055504540353015 20 2525 30 3

Pagina 3 - Table of Contents

825876530 35 402520181614121030 35 40–50 5987610 15 20 25–50 5106055504540353015 20 2525 30 35 40–5 0 5 101520254.03.53.02.51.21.11.00.9Indoor air tem

Pagina 4 - 1. OPERATING RANGE

92510 9 8 730 35 402510121416182030 35 40–50 513121110 9 810 15 20 25–50 51060555045403515 20 25251.21.11.00.930 35 40–5 0 5 101520254.03.53.02.527°C1

Pagina 5 - 2. SPECIFICATIONS

102510121416182030 35 40–50 513121110 9 8 710 15 20 25–50 51060555045403515 20 25251.21.11.00.930 35 40–50 5101520254.03.53.02.527°C17°C24°CIndoor air

Pagina 6 - 2-2-1. Outdoor Unit

116. ELECTRICAL DATA6-1. Electric Wiring DiagramOutdoor Unit AE4MI91AHCAUTIONWHTBLKWHTWHTBRN(RED)WHTWHTWHTYELYELYELYELYELYELYELYELYELYELYELYELYELYELYE

Pagina 7

12Installation Site Selection7-1. Indoor UnitAVOID:●direct sunlight.●nearby heat sources that may affect performance of theunit.●areas where leakage

Pagina 8 - AIR INTAKE

13In the case below, a joint for connecting tubes of different sizes is needed when connecting the inter-unit tube (φ9.52)to the outdoor unit valve (φ

Pagina 9 - Indoor unit

147-2. Outdoor UnitAVOID:●heat sources, exhaust fans, etc. (Fig. 3)●damp, humid or uneven locations.DO:●choose a place as cool as possible.●choose a

Pagina 10 - • Heating Characteristics

15Indoor unit AIndoor unit BIndoor unit CIndoor unit DBe sure to connect indoor and outdoor units only in combinations that are listed in the catalog

Pagina 11

167-4. Recommended Wire Length and DiameterRegulations on wiring diameter differ from locality to locality. For field wiring requirements, please ref

Pagina 12

iImportant! Please Read Before StartingThis air conditioning system meets strict safety andoperating standards. As the installer or service person,it

Pagina 13 - • Heating

178. FUNCTIONS8-1. Defrost Detection and End8-1-1. Non-stop defrostingDefrost sequence4-way valve ONDefrost detection occurs in either of the followin

Pagina 14 - 6. ELECTRICAL DATA

188-2. Current Control● The operating current may rise as a result of causes including increasing heating or cooling loads or decreases in power volta

Pagina 15 - 7. INSTALLATION INSTRUCTIONS

198-5-2. HEAT operation(1) The fan speed is changed as shown in the figure below, based on the outdoor air temperature and the operating frequency.(2)

Pagina 16

209. TROUBLESHOOTING9-1. Conditions That Do Not Represent Trouble Both the indoor unit and outdoor unit include electronic control circuits. Be sure

Pagina 17 - 7-2. Outdoor Unit

219-2. Outdoor Unit Trouble DiagnosticsIf a protective device has activated or there is a sensor failure in the outdoor unit, the 6 error monitor lamp

Pagina 18 - Unit: mm

229-3. Checking the Outdoor System9-3-1. Checking the outdoor unit• Apply 220 V AC between terminals 1 and 2 on the outdoor unit 3P terminal block.•

Pagina 19 - 7-5. Wiring System Diagram

239-4. Unit Problems and Inspection Points• For details about the inspection points, refer to Inspection points for each part.Indoor unitIndoor unitO

Pagina 20 - 8. FUNCTIONS

249-4-1. Outdoor control circuit boardRefer to 9-3-1. Checking the outdoor unit.NOTE: Do not remove or insert the outdoor control circuit board conne

Pagina 21 - 8-5. Outdoor Fan Control

259-4-9. Electric expansion valve● When replacing the electric expansion valve and coil, be sure to attach the connectors in the correct positions. L

Pagina 22 - -6. Control at HEAT Start-up

269-5. Explanation of Functionssnoitidnoc/lortnoC noitarepotinU noitanalpxELAITINI .NOsirekaerB tinuroodtuodnaroodniehtotdeilppussirewoPsniamertinueht

Pagina 23 - 9. TROUBLESHOOTING

Table of ContentsPage1. OPERATING RANGE ...

Pagina 24

27snoitidnoc/lortnoC noitarepotinU noitanalpxETAEH When defrost operationbegins, frost has formedon the outdoor unit(when the ambient airtemperature i

Pagina 25

28snoitidnoc/lortnoC noitarepotinU noitanalpxELOOCThe ON/OFF operationbutton on the remotecontroller is pressed.●●●.setanimullipmalnoitarepoehTnaftese

Pagina 26

29snoitidnoc/lortnoC noitarepotinU noitanalpxEROSNESYRDoperationFFO/NOehTbutton on the remotecontroller is pressed.●●●.setanimullipmalnoitarepoehTnaft

Pagina 27

3010. REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN SERVICING UNIT10-1. Characteristics of New Refrigerant R410A10-1-1. What is New Refrigerant R410A

Pagina 28 - 9-4-11. Breaker

31●Tubing precautionsRefrigerant R410A is more easily affected by dust or moisture compared with R22, thus be sure to temporarilycover the ends of the

Pagina 29 - 9-5. Explanation of Functions

3210-3. Tools Specifically for R410A●For servicing, use the following tools for R410A●To prevent other refrigerants (R22, R407C) from being mistakenl

Pagina 30

3310-5. In Case of Compressor Malfunction10-5-1. Procedure for replacing compressor(1) Recovering refrigerant● Any remaining refrigerant inside the

Pagina 31

34(5) Recharging● Be sure to charge the specified amount ofrefrigerant in liquid state using the service portof the wide tube service valve. The prope

Pagina 32 - (1/f fluctuation fan)

3510-6. In Case Refrigerant is Leaking(1) Detecting Leaks● Use the detector for R410A to locate refrigerant leakpoints. (2) Recovering refrigerant● N

Pagina 33 - 10. REFRIGERANT R410A:

36(6) Recharging● Be sure to charge the specified amount ofrefrigerant in liquid state using the service portof the wide tube service valve. The prope

Pagina 34

11. OPERATING RANGETemperature Indoor Air Intake Temp. Outdoor Air Intake Temp.CoolingMaximum 32°C D.B. / 23°C W.B. 43°C D.B.Minimum 19°C D.B. / 14°C

Pagina 35

3710-7. Charging Additional Refrigerant10-7-1. When Tubes are Extended●Observe the proper amount of refrigerant as stated in this service manual or

Pagina 36

38UNIT COMBINATION TABLESAPPENDIXBe sure to operate the air conditioning system only when 2 ormore indoor units have been installed. If operated with

Pagina 37

Single-room operationIndoor unitIndoor Unit Capacity (kW)ConbinationRoom A Room B Room C Room D Total Performance Power Input (W) Current (A)Min.

Pagina 38

Three-room operatioIndoor unitIndoor Unit Capacity (kW)ConbinationRoom A Room B Room C Room D Total Performance Power Input (W) Current (A)Min.

Pagina 39

Four-room operationIndoor unitIndoor Unit Capacity (kW)ConbinationRoom A Room B Room C Room D Total Performance Power Input (W) Current (A)Min.

Pagina 40

ARGOCLIMA SPAGALLARATE-ITALY

Pagina 41 - APPENDIX

22. SPECIFICATIONS2-1. Unit SpecificationsOutdoor Unit AE4MI91AH Type 4-room multi outdoor unit Number of connectable indoor units 4 Maximum capac

Pagina 42 - 2-room operation

32-2. Major Component Specifications2-2-1. Outdoor UnitOutdoor Unit AE4MI91AHDATA SUBJECT TO CHANGE WITHOUT NOTICE.Control PCB / HIC PCB / Filter PCB

Pagina 44 - 4-room operation

53. DIMENSIONAL DATAOutdoor Unit AE4MI91AH1888094033.7Wide tube service valve ø9.52 (3/8")Wide tube service valve ø12.7 (1/2")Narrow tube se

Pagina 45 - GALLARATE-ITALY

4. REFRIGERANT FLOW DIAGRAM6Outdoor Unit AE4MI91AH4-Room Multi-Refrigerant Tubing System DiagramUnit: mmService valve on wide tube sideService valve o