Argo FC Series Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 9
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
ITA ENG FRA ESP DEU POR
6-1622192 REV.14 30/07/2012 9/9
GUARANTEE: The producer’s guarantee is valid in compliance with the law, from the date stamped on the product and is limited to repiar work and
free replacement of pieces recognised as faulty for problems with the qualità and / or materials due to bad workmanship. The guarantee does not
cover damages or defect due to external causes, wrong maintenance practices, overload, normal wear, choice of the wrong product, wrong installa-
tion, or any cause for which the manufacturer cannot held responsible. The guarantee is not valid if the product has been tempered with.
The data above mentioned are merely indicative. we all decline all responsability for range reductions or non-workings due to environmental interfe-
rences. The responsability of the manufacturer for damages caused by accidents of any type due to its own defective products is solely the responsa-
bility provided by the italian law.
Technical details
Power voltage 230 Vac +15% -15%
Accessory supply 24 Vac 4,5W MAX
Motor output 230Vac 600W MAX cosφ > 0.8
Flashing light output 230 Vac 60W MAX
Electric lock output 12Vac 1A MAX (12VA)
“Gate Open”
warning light output
24Vac 3W MAX
Motor output voltrage
regulation (couple
regulation trimmer)
from 60% (± 20%) al 95% (MAX) of line voltage
Working time from 5 s a 120 s
Braking time In proportion to operational time
Pause time from 3 s to 3 minutes
2nd wing delay from 0 to 60 s
Absorption 5W MAX
Operating temperature -10°C ... +60°C
Receiver frequency
and reception type
433.92 MHz
super-reactive
433.92 MHz
superheterodyne
30.875 MHz
quarzated
290 MHz
super-reactive
306 MHz
super-reactive
40.665 MHz
quarzated
Reception available Fixed-code
Rolling-code
Fixed-code
Rolling-code
Fixed-code Fixed-code Fixed-code Fixed-code
Rolling-code
Turned antenna
impedance
50
Number of codes
available
4096 (FIXED CODE reception)
18 billion of billions (ROLLING CODE reception)
Maximum range (with turned
antenna and under optimal
conditions)
30 - 80 m in
free space
50 - 120 m in
free space
50 - 120 m in
free space
50 - 100 m in
free space
50 - 100 m in
free space
50 - 120 m in
free space
Maximim number of
transmitters
1000 with B.RO 1000 memory module
ARGO for 1-2 MOTORS
* Device not for UE market.
11.2 Additional radio channel.
If the radio receiver operates on card bases, there is the possibility to fit the control unit with an output block for an additional radio channel (with N.A.
contact). However, the additional channel is not available if you are using the hybrid module contained as standard in the control unit.
11.3 Exit electronic locking.
It is possible to link directly to central unit an electronic locking powered 12 Vac 12 W max., for arresting closing movement. Besides, it is possible to
variate working-time of electronic locking (if setted by dip-switch 2), following the instructions in paragraph 8.2.
11.4 Open gate warning light.
Over exit open gate warning light, It is possible to connect a load of 230Vac 3W max, that signalizes when gate is not close. Such warning is off with
close gate, blinks with the same frequencies of flashing light if gate is on, stays switches on when gate is open.
11.5 Pedestrian function.
The switchboard is outfit with a pedestrian function: once opened, it totally activates only a single wing. It is possible to activate the pedestrian also by
a telecontrol.
PLEASE NOTE: Step-by-step direction has always priority on pedestrian function; in fact, if step-by-step and pedestrian commands are strictly
executed, the central unit always performs step-by-step impulse.
Vista de pagina 8
1 2 3 4 5 6 7 8 9

Comentarios a estos manuales

Sin comentarios