INTRODUCTION
This manual is intended to familiarize the installer
and user of the Electric Hydronic Block with its
installation, operation and maintenance so as to
assure its normal trouble free operation.
Argo electric boilers are designed and manufactured
with quality components for maximum life and
durability and require minimum service. To insure
a satisfactory installation it is imperative that the
instructions be followed carefully before operating
the heating system. Failure to do so may result in
breach of warranty.
PRODUCT DESCRIPTION
The Electric Hydronic Block is a heating device that
converts electrical energy to heat energy through
the medium of water. The simplied theory of this
conversion is as follows:
Electrical Energy x Conversion Factor = Energy
– Or –
Kilowatts Of Electricity Used Per Hour x 3412 = British
Thermal Units (Btuh) Available Per Hour For Heating.
This information is the basis used to establish Elec-
tric Hydronic Block ratings (See Table 1 on page 4).
Since the conversion process requires no combus-
tion, the boiler operates with the highest possible
efciency.
The Electric Hydronic Block is constructed with
a cast iron boiler that conforms to the American
Society of Mechanical Engineers (ASME) Boiler &
Pressure Vessel Code. The interior design allows
just enough water to be present for proper heating
element operation - no excess water is stored which
would cause undersirable thermal losses and longer
recovery times.
The control system is assembled in a modular pack-
age thus keeping the overall size and weight of the
Electric Hydronic Block to a minimum. The construc-
tion of the entire Electric Hydronic Block conforms to
Canadian Standards Association (CSA) Standards
for Safety for Electric Boilers.
! !
! !
WARNINGS
WARNING
1. BOILER SIZING IS CRUCIAL. The maximum
hourly heat loss for each heated space should
be calculated in accordance with the proce-
dures describes in The Hydronics Institute
(I=B=R) manual H-22 (Heat Loss Calculation
Guide), or by any other method which is suit-
able for local conditions, provided the results
are in substantial agreement. Select the ap-
propriate boiler based on accurate heat loss
calculation. DO NOT OVERSIZE THE BOILER,
AS SIZING IS CRITICAL FOR IN-FLOOR RADI-
ANT HEAT APPLICATIONS.
2. Keep boiler area clear and free from combus-
tible materials, gasoline and other ammable
vapors and liquids.
3. DO NOT obstruct air openings to the boiler
room.
4. Modication, substitution or elimination
of factory equipped, supplied or specied
components may result in property damage,
personal injury or the loss of life.
5. TO THE OWNER: Installation and service of
this boiler must be performed by a qualied
installer.
6. TO THE INSTALLER: Leave all instructions
with the boiler for future reference.
7. When this product is installed in the Com-
monwealth of Massachusetts the installation
must be performed by a licensed plumber or
licensed gas tter.*
* In other areas, consult your local codes.
WARNING
All installations of boilers should be done
only by a qualied expert and in accordance
with the appropriate Argo manual. Installing
a boiler or any other electric appliance with
improper methods or materials may result in
serious injury or death due to re.